LASER MACHINE FACTORY

17 Years Manufacturing Experience

Common Fault Alarm and Solution Of Fiber Laser Cutting Machine !

Common Fault Alarm and Solution Of Fiber Laser Cutting Machine 

Alarm location

Alarm name

Alarm reason and inspection method
 

 

 

Floating head alarm

Body capacitance becomes smaller

1. Nozzle is not installed

2.The ceramic ring is loose

3.Wiring problem

Abnormally large capacitance

Calibration problem, re-calibrate

Servo alarm 1. Z axis servo is not turned on

2.There is a problem with the servo wiring, please check all servo

plugs.

Z+ Limit valid

 Z+ limit trigger

Z- Limit valid

Z- limit trigger

Communication time out

1.The network cable is not connected

2. Reset height controller IP

3 Height controller is closed

Servo alarm

Alarm code: 910, 710, 720

1. Servo is not turned on

2. There is a

problem with the servo wiring, please check all servo plugs.

Limit alarm

Y+ Limit

Limit trigger

Y-Limit

Something hits the limit

X+ Limit

Replace the limit problem

X- Limit

The adapter board is faulty

The cutting effect suddenly deteriorates

1. No calibration after material replacement

2. The nozzle is not clean or broken

3. Insufficient cutting air pressure

4.镜The lens is dirty or damaged

KNOPPO LASER has a solution for any laser cutting requirement you may have. Sales – Installations – Service – Support – Training – your trusted laser partner .

1 (2)


Post time: Jul-07-2021